PUWER Inspection: Scope, Records and Suitable Intervals

A Regulation 6 inspection is not a blanket legal requirement to inspect every item of work equipment on a fixed schedule. Under the Provision and Use of Work Equipment Regulations 1998 (PUWER), an inspection is required when safety depends on correct installation, or when deterioration could create danger. The duty is risk-triggered, and the reason for each inspection interval should be clear enough to explain to an auditor or inspector.
Key points
- Regulation 6 of PUWER 1998 sets the inspection duty; it does not prescribe a general inspection interval for machinery.
- Inspect after installation or assembly in specified circumstances, at suitable intervals where deterioration could cause danger, and after relevant exceptional circumstances.
- Set intervals by considering what can deteriorate, how quickly it may do so and the consequences.
- Record the result of each required inspection and keep it until the next inspection is recorded.
- A Regulation 6 inspection, an operator’s pre-use check, maintenance and a wider PUWER assessment serve different purposes.
When does Regulation 6 require an inspection?
Regulation 6 of PUWER 1998 applies in two main situations:
- Safety depends on installation conditions. Inspect the equipment after installation and before it is put into service for the first time, or after assembly at a new site or location.
- Deterioration could lead to danger. If equipment is exposed to conditions that may cause dangerous deterioration, inspect it at suitable intervals and whenever exceptional circumstances liable to jeopardise its safety occur.
Exceptional circumstances can include damage, an incident, significant repair or alteration, or a substantial change in use. The practical test is whether the event could affect the equipment’s safety, not whether it appears on a generic checklist.
This means not every tool or machine needs a formal Regulation 6 inspection at the same interval. The duty holder should identify which equipment meets the test, what the inspection needs to cover and why the timing is appropriate. The Health and Safety Executive’s inspection guidance and Approved Code of Practice (ACOP) L22 provide further guidance.
How should you set a suitable interval?
There is no statutory inspection frequency for machinery under PUWER. A suitable interval should be based on the likelihood and rate of deterioration, and the risk that deterioration creates. ACOP L22 advises considering the equipment, how it is used and the conditions it is exposed to.
A practical way to set and review an interval is to:
- Identify what could deteriorate: components, safeguards, fixings, settings or other features that matter to safe operation.
- Consider the conditions: use, loading, environment, cleaning, vibration, impact and any other relevant exposure.
- Estimate how quickly deterioration could become hazardous: use operating experience, inspection findings, maintenance history, manufacturer information and relevant industry guidance.
- Consider the consequence: how serious could the outcome be if deterioration went undetected?
- Set an interval with a margin: plan to inspect before likely deterioration could become dangerous, then adjust the interval in response to evidence.
The reasoning should be recorded alongside the interval. If repeated inspections find little deterioration, that may support a review; if defects are found, or conditions change, the interval may need to shorten. Do not extend an interval simply because no incident has occurred.
Three examples of interval reasoning
A machine guard: Consider how the guard is used and what might affect its continued effectiveness. Hinges, fixings and panels may be damaged by impact, vibration or frequent access. For an interlocked guard, the inspection may also need to confirm that the guard and interlock still operate as intended. A machine used frequently in a harsh environment may need closer attention than one used occasionally in stable conditions. The interval should reflect the likely deterioration and the risk if the guard no longer protects as intended, not a universal PUWER number.

A lifting accessory within a machine: First establish whether the item is a lifting accessory covered by the Lifting Operations and Lifting Equipment Regulations 1998 (LOLER). If it is, the LOLER examination regime applies: lifting accessories are examined every six months unless a different period is specified in a written scheme of examination by a competent person. Regulation 6 of PUWER excludes work equipment for lifting loads from its inspection duty. Do not substitute a PUWER interval for the applicable LOLER requirements. For components that are not LOLER lifting equipment, determine the relevant duty and inspection scope rather than assuming that the example applies.
Pressure equipment or pipework: Consider whether corrosion, vibration, pressure cycling, temperature or other conditions could cause deterioration that leads to danger. Where the item forms part of a pressure system covered by the Pressure Systems Safety Regulations 2000 (PSSR), the written scheme of examination (WSE) and its competent person determine the required examination scope and timing. A PUWER inspection should not be used instead of a PSSR examination where one is required.
What is a Regulation 6 inspection not?
A Regulation 6 inspection is not the same as:
- A pre-use check: an operator-level check for obvious problems before use. Such checks can be an important control, but they do not replace a required Regulation 6 inspection.
- Maintenance: work to preserve or restore equipment. Maintenance is addressed separately under Regulation 5 of PUWER; an inspection may identify a need for maintenance, but the two are not interchangeable.
- A wider PUWER assessment: a broader review of relevant duties and how work equipment is used. A Regulation 6 inspection may sit within an inspection regime, but it does not, on its own, amount to a full assessment.
Put simply, pre-use checks help detect immediate problems, planned maintenance helps keep equipment in good order, and a Regulation 6 inspection checks whether specified safety conditions are being maintained. A wider assessment considers the equipment and relevant PUWER duties in context. For more on that distinction, see our article on what a PUWER assessment covers.
Who can carry out the inspection?
The inspection must be done by a competent person: someone with enough knowledge, experience and ability for the inspection in question. Competence is task-specific: a person able to carry out a straightforward visual check may not be competent to make measurements, test a safety-related function or assess complex automated equipment.
The inspection should match the risk and purpose. It may involve visual examination, functional checks, measurement or testing. A visual check alone cannot verify a function that needs to be tested; for example, pressing an interlock button does not establish that the machine actually stops safely.

Independence is not a universal requirement under Regulation 6. However, sites should consider whether the person carrying out the inspection can identify and report defects objectively. Particularly where they also operate or maintain the equipment.
What should the inspection record contain?
Regulation 6 requires the result of each inspection to be recorded. The record must be kept until the next inspection under Regulation 6 is recorded. The regulation does not set a fixed retention period or prescribe a universal template; the record should provide a clear, traceable account of what was inspected and what was found.
ACOP L22 recommends recording identifying information and the inspection outcome. A useful record set should include:
- asset identification and normal location;
- inspection date and the name of the person who carried it out;
- what was checked and, where useful, the inspection method;
- findings, including faults or defects;
- actions taken or required, and to whom faults were reported; and
- the next due date and the reason for the chosen interval.
Keep records organised so the current inspection can be linked to the previous one and any follow-up actions. A gap in that evidence chain makes it difficult to demonstrate that the inspection regime is being followed. PUWER also requires physical evidence of the last required inspection when relevant equipment leaves an employer’s undertaking, or is brought into another undertaking.
Common inspection problems we see on site
Some sites have no formal inspection regime. Others have intervals inherited from a previous manager, with no written rationale. We also see sheets marked only “satisfactory”, records that become inaccessible when a staff member leaves, and inspections performed by the machine operator without enough challenge or task-specific competence.
A further gap is recording that an interlock was pressed without confirming that the machine stopped. The record should reflect the check that was actually performed, not simply a tick against a heading.

How can you make the regime auditable?
Start with an asset register that identifies equipment requiring Regulation 6 inspection and records why. For each item, document the deterioration mechanisms, the inspection scope, the interval and the evidence used to review that decision. Then ensure inspections are completed by people competent for the work, findings are acted on and records remain accessible until the next inspection is recorded.
Safemach carries out PUWER inspections, supports organisations to build asset registers and inspection regimes, and can engineer, supply and install guarding and safety systems where findings call for them. We also provide PUWER assessor training for organisations developing in-house competence. To discuss an inspection regime for your equipment, contact Safemach.