A DSEAR risk assessment should help you make practical decisions about dangerous substances, possible explosive atmospheres and the controls needed to keep people safe. A hazardous-area drawing alone is not enough: the assessment must reflect how your site actually operates, identify ignition risks and set out any actions that remain.

The method below follows the requirements of the Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR, SI 2002/2776), supported by the HSE’s Approved Code of Practice and guidance, L138. DSEAR implements the workplace requirements of ATEX 137 (Directive 1999/92/EC) in Great Britain.

1. Define the scope and inventory the substances

Start by establishing what dangerous substances are present, or could reasonably be present, and how they are used. Do not rely only on a purchasing list or safety data sheets (SDSs): check the process and the workplace as well.

For each substance, record:

  • Its name, relevant hazards and available SDS.
  • The maximum quantity present, including typical operating quantities.
  • Its form: liquid, gas, vapour, mist or combustible dust.
  • Where it is received, stored, transferred, used and disposed of.
  • The containers, vessels, pipework or equipment that hold it.

Include substances that may be easy to overlook: waste, residues, cleaning products, maintenance chemicals, dust collected by extraction systems and materials brought on site only occasionally. Consider whether the process could create a dangerous substance, such as a flammable vapour or combustible dust.

What you need: purchasing and stock records, SDSs, process information, maintenance and cleaning procedures, and a site walkdown with people who know the work.

Output: a substance inventory listing substances, quantities, physical form and locations.

Technician checking chemical containers in an organised factory storage area

2. Identify where releases and explosive atmospheres could occur

Go to the plant, not just the drawing. Walk through normal operations and foreseeable abnormal conditions with operators and maintenance staff. Identify where a dangerous substance might escape, how it could disperse and whether it could form an explosive atmosphere.

Consider potential releases during:

  • Filling, emptying, transfer, sampling and routine process operations.
  • Leaks from seals, valves, flanges, hoses, pumps and connections.
  • Spills, dust deposits, cleaning and waste handling.
  • Maintenance, equipment opening, blockages and breakdowns.
  • Upset conditions, including failures that could reasonably be anticipated.

Assess the role of ventilation too. Note the type, location and reliability of natural or mechanical ventilation, and whether an atmosphere would disperse quickly or could accumulate in a pit, enclosure or poorly ventilated area. Where ventilation is relied on as a control, record what happens if it fails.

What you need: current layouts and process diagrams, operating and maintenance procedures, ventilation information, and input from people who work with the equipment.

Output: a list of release scenarios and locations, including the assumptions made about frequency, duration and ventilation.

Safety engineer carrying out a factory walkdown beside process pipework and extraction

3. Classify the hazardous areas

Where explosive atmospheres may occur, DSEAR requires the areas to be classified and the classification to be documented, including the extent of each area. This is commonly known as hazardous area classification (HAC).

For gases and vapours, the zones are 0, 1 and 2; for dust, they are 20, 21 and 22. In brief, the numbers distinguish areas where an explosive atmosphere is present continuously or frequently, likely to occur occasionally in normal operation, or unlikely in normal operation and present only briefly if it occurs.

The practical task is to decide which classification fits each release scenario and how far the hazardous area extends. That judgement depends on the release characteristics, the substance, operating conditions and ventilation. It is not a guess based on the presence of a flammable liquid, nor a boundary automatically set by the walls of a room.

Classification matters because it informs decisions about equipment and protective measures downstream. Equipment used in a classified area must be suitable for the relevant zone and the substance and conditions involved.

What you need: the release scenarios from Step 2, substance properties, process and ventilation details, and a classification methodology suited to the installation.

Output: a hazardous-area classification drawing or schedule that records zone types and their extents. The basis and assumptions should be clear enough for another competent person to understand.

4. Identify and control ignition sources

For each classified area, and for relevant release scenarios outside classified areas, identify ignition sources that are present, could be introduced or could arise during maintenance. Consider the 13 sources in the standard framework:

  1. Hot surfaces.
  2. Flames and hot gases.
  3. Mechanically generated sparks.
  4. Electrical apparatus.
  5. Stray currents.
  6. Static electricity.
  7. Lightning.
  8. Electromagnetic fields.
  9. Ionising radiation.
  10. Ultrasound.
  11. Compression ignition.
  12. Exothermic reactions.
  13. Other sources.

For each source, ask whether it could occur in the area and whether it could ignite the substance involved. A useful review includes fixed machinery and electrical equipment, hot work, portable tools, vehicles, clothing and footwear, and activities that could create static charge. Include maintenance and contractor work, not just the normal production set-up.

Controls might include selecting equipment suitable for the zone, bonding and earthing, controlling hot work, managing vehicle access or preventing incompatible equipment from entering the area. Record how each control is achieved and maintained.

What you need: the zone drawing, equipment and electrical records, maintenance and permit procedures, and knowledge of the actual work carried out.

Output: an ignition source schedule mapped against the zones, showing sources identified and the controls in place or required.

Engineer inspecting industrial equipment and motor in a manufacturing environment

5. Assess the residual risk, document and set actions

Bring the findings together and decide whether the existing measures are adequate. Consider who could be affected, including employees, contractors and visitors, and the likely consequences if a release, ignition or control failure occurs.

Where more is needed, set out actions that are specific and trackable. For each one, record:

  • The issue and the required improvement.
  • A named owner and a realistic completion date.
  • Any interim precautions needed while the action is open.
  • How completion will be checked and recorded.

Set a review date and identify triggers for an earlier review. These may include changes to substances, quantities, equipment, layout, ventilation, operating methods or maintenance arrangements, as well as incidents, near misses or evidence that an assessment assumption is no longer valid.

DSEAR requires the assessment to be suitable and sufficient, and to be reviewed when it may no longer be valid or there has been a significant change. Keep the assessment and associated records under control so the people responsible for the actions can use them.

What you need: the outputs from the previous steps, records of existing controls, information about people and activities at risk, and a process for assigning and tracking actions.

Output: a documented assessment that records the findings, evaluates the risks, sets out controls and assigns any outstanding actions. Where applicable, this informs the explosion protection document required by DSEAR.

What a defensible assessment actually contains

Use this checklist to judge whether the work gives you something you can act on:

  • A substance inventory, including quantities, physical forms and locations.
  • The findings from the site assessment and the release scenarios considered.
  • Hazardous-area classifications, with clear extents and documented assumptions.
  • An ignition-source assessment and the controls for relevant sources.
  • The basis for equipment selection that follows from the zone classification.
  • An evaluation of risks to people and the adequacy of existing controls.
  • Actions with named owners, due dates and any interim measures.
  • A review arrangement that identifies dates and change triggers.

A list of hazards or a zoning drawing without the supporting risk evaluation and actions is not the whole assessment.

What we see that undermines an otherwise good assessment

An assessment can be thorough on paper and still fail to represent the workplace. Common problems include:

  • Classification completed using a drawing that no longer matches the plant.
  • Zones ending at a room boundary without assessing the likely extent of a release.
  • Extract systems omitted from the assessment, or treated as reliable without considering failure.
  • Mobile equipment and forklift truck movements not considered.
  • Hazards identified, but no actions assigned to address them.

These gaps are often found by checking the assessment against the operating site and speaking with the people who use, clean and maintain the equipment.

Who is competent to do this?

DSEAR Approved Code of Practice L138 expects the assessment to be carried out by someone with the necessary competence. In practice, that means having enough knowledge, training and experience to understand the substances, process, potential releases, ventilation and classification methodology, and to evaluate the controls.

Competence is task-specific. A general risk assessor using a template may not have the experience to classify a complex process or determine whether equipment is suitable for a hazardous area. The duty holder remains responsible for making sure the assessment is adequate and that specialist input is brought in where needed.

Safemach carries out DSEAR and ATEX assessments and hazardous-area classification, as well as engineering, supplying and installing protective measures that follow from the findings. To discuss an assessment, contact Safemach. If you also need machinery risks reviewed, see our PUWER inspection service.